Extra room power heat duct instructions, Wiring instructions, Wiring diagram - internal thermodisk (864 ho) – Avalon Firestyles Extra Room Power Heat Duct User Manual
Page 6: Power supply, Rheostat junction box blower assembly
![background image](https://www.manualsdir.com/files/772826/content/doc006.png)
Extra Room Power Heat Duct Instructions
SKU 98500769
Page 6 of 11
12/2/13 - 17601067
© Travis Industries, Inc.
Wiring Instructions
Warning: All wiring should be done by a qualified electrician and shall be in compliance with
local codes and with the current National Electric Code ANSI/NFPA 70 (in the U.S.), or
with the current CSC22.1 Canadian Electric Code (in Canada).
Warning: Make sure the fireplace electrical circuit is disabled prior to working on electrical
hookup.
Wiring Diagram – No Internal Thermodisk
(864 TRV & ST, 564 HO, 3615, 4415, 6015, Xtreme 6020 II)
Hot
(black)
Common
(white)
Ground
(green)
Power Supply
Hot
(black)
Common
(white)
Ground
(green)
Rheostat
Junction Box
Blower
Assembly
Wiring Diagram - Internal Thermodisk
(864 HO)
Rheostat
Junction
Box
Hot
(black)
Common
(white)
Ground
(green)
Power Heat
Duct Thermoisk
Fireplace AC
Components
Molex
Connector
Molex
Connector
Hot
(black)
Common
(white)
Ground
(green)
Hot
(black)
Common
(white)
Ground
(green)
Heat Duct
Rheostat
Hot
(black)
Common
(white)
Ground
(green)
Hot
(black)
Common
(white)
Ground
(green)
Grounded
to Blower
Power Supply
Hot
(black)
Common
(white)
Ground
(green)
Heat Duct
Blower
Blower
Junction
Box
Optional Second Heat
Duct (same rheostat and
blower wiring as above)
Hot
(black)
Common
(white)
Ground
(green)
Fireplace
Thermodisk
Pass-Through
Wire
Electrical Connector
(molex 3 wire)