Avalon Firestyles Extra Room Power Heat Duct User Manual
Extra room power heat duct instructions, Compatibility, Packing list
![background image](https://www.manualsdir.com/files/772826/content/doc001.png)
Extra Room Power Heat Duct Instructions
SKU 98500769
Page 1 of 11
12/2/13 - 17601067
© Travis Industries, Inc.
Compatibility
• 564
HO
• 864 TRV, ST, and HO
• Xtreme
6020
• 3615, 4415, and 6015
• 36 CF ST and Pier -- NOTE: Requires the 1080 CF/36 CF ST-Pier wiring kit – sku 94400995.
• 1080
--
NOTE: Requires the 1080 CF/36 CF ST-Pier wiring kit – sku 94400995.
Packing List
• Blower Box
• Duct Adapter (6” Round to 10” by 3-1/4”)
• 6” Round Duct (2’ to 20’ Length)
• Rheostat
• Rheostat
Knob
• Grill (with 2 screws)
• Wall Adapter
• 2 Junction Boxes
• Cover Plate (w/ screws)
• Floor Boot
• 4 #8 Sheet Metal Screws
• Wall Mounting Brackets (2)
• Electrical Connector (molex 3-wire)
• Starter Ring
• (4) #8 Wood Screws
• (2) Romex Cable Clamp
• Thermodisk (for 36 and 44 DV models with modulating remotes –contact Travis Ind. for details)
• Thermodisk Pass-Through Wire (864 HO only)
Installation Warnings
Warning: This kit must be installed as specified in these instructions. Do not modify any
component.
Warning: Use of any external blower other than the Travis Power Heat Duct Blower will void the
warranty and listing of this appliance and may create a fire hazard.
Note:
The power heat duct must be installed by a qualified service technician.
Note:
Some building codes may require the use of firestop spacers whenever the duct passes
from room to room.
Note:
When routing ducts through a cold area (e.g. crawl space) we recommend insulating the
duct with fiberglass insulation. If paper-backed insulation is used, the paper can not
contact the duct.