Installation Overview
The overview below details installation concerns for the type of heater being used. Install the heat duct
prior to installing drywall.
864 HO
36 CF ST/Pier
1080 CF
NOTE: These fireplaces
use an internal thermodisk
to automatically turn the
blower on when the
fireplace reaches suitable
temperature (note: the
rheostat must be turned on
for this feature to work).
The power heat duct will
run until the fireplace has
cooled sufficiently.
Electrical
Source
Starter Ring
Use 10" x 3-1/4"
wall stack (duct)
when passing
through tight
areas.
6" Duct
Duct Adapter
(6" Round to 10" x 3-1/4")
Floor
Boot
Grill
Rheostat
(with cover plate)
Junction Box
Wall Adapter
(for use on
2 x 4 walls)
Heat Duct
Electrical
Wiring
Blower
Box
Maximum Duct
Length = 20'
864 TRV
864 ST
564 HO
3615, 4415, 6015
Xtreme 6020 II
NOTE: These
fireplaces require the
power heat duct to be
manually controlled.
The homeowner must
turn the blower on and
off manually. The
blower will remain on
even if the fireplace is
turned off.
Starter Ring
Use 10” x 3-1/4”
wall stack (duct)
when passing
through tight
areas.
6" Duct
Duct Adapter
(6” Round to 10” x 3-1/4”)
Floor
Boot
Grill
Rheostat
(with cover plate)
Junction Box
Wall Adapter
(for use on
2 x 4 walls)
Blower
Box
Maximum Duct
Length = 20'
Electrical Source