- For Qualified Installers Only!
3
Close the door. Make sure the door is centered and the attachment screws are tightened to form a
seal around the door opening.
4
Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot. Start
the main burner. Leak test all gas joints again.
5
Check the pilot flame to make sure it looks like the illustration below. Adjust the pilot flame if
necessary.
The pilot flame should impinge the top 3/8” (10 mm)
of the thermopile. If it does not, you may need to
turn the pilot up.
3/8” (10 mm)
Thermopile
Pilot Hood
Thermocouple
To adjust the pilot flame, remove the cover screw (and
gasket) and turn the needle valve. Clockwise lowers
the flame while counter-clockwise raises it.
PILOT ADJ
T
O
L
PI
ON
OFF
Standard
Screwdriver
Micro (1/16”)
Standard
Screwdriver
The cover screw and
gasket must be
replaced to prevent gas
from leaking
Cover Screw
Cover Screw Gasket
Needle Valve