Avalon Firestyles D-V-1996 User Manual
Page 20

P
AGE
20
I
NSERT
I
NSTALLATION
(
CONT
.)
- For Qualified Installers Only!
Insert Placement
The Insert Must be
Placed 11-1/4" (286 mm)
into the Fireplace.
Run the brown and red
wire (for the on/off switch)
to the right side along the
facing.
Run the power cord to
either side of the insert
along the facing.
The insert must be in place with
the gas line and vent attached
prior to installing the panels.
Min. 27-3/4" (705 mm) WIde - includes
6" (150 mm) for gas line installation
Min. 21-1/2"
(550 mm) Tall -
includes 2" (50
mm) for vent
installation
The gas line faces to the rear
and its center is 4-1/4" (108 mm)
back from the fireplace opening,
1-5/8" (41 mm) above the
hearth, and 7-1/2" (191 mm)
from the center of the insert.
NOTE:
When using the 45° vent, an
additional 4" (100 mm) is
required behind the rear
edge of the baseplate for
vent hook-up.
Use the leveling bolts for
fireplaces with recessed
floors (included with the
surround panels).
•
Insert must be placed so no combustibles are within, or can swing within 36" (910 mm) of the front
of the heater (e.g. drapes, doors)
•
The insert may be placed inside a masonry fireplace or listed zero-clearance (metal) fireplace
•
The insert must be installed in a level, undamaged fireplace (damage must be repaired prior to
installation).
•
The insert must maintain 10" (254 mm) clearance to sidewalls (measure from the upper top)
•
Non-combustible facing (e.g. brick, tile) must extend 8" (203 mm) minimum from the side and 12"
(305 mm) to the top of the insert (measure from the upper top)
•
Combustible mantles must be a minimum 17-1/2" (445 mm) above the top of the insert (measure
from the upper top)
Floor Protection
•
The heater must be installed on a non-combustible hearth and may not extend over combustible
flooring