Tove, Nstallation, Cont – Avalon Firestyles D-V-1996 User Manual

Page 14

background image

P

AGE

14

S

TOVE

I

NSTALLATION

(

CONT

.)

- For Qualified Installers Only!

Approved Venting Configurations for
Vertical Terminations with (or without)
Two 45

°

Elbows

10' (3 M) Minimum System Height
(with or without offsets)

33' (10 M) Maximum System Height

6' (1.8 M) Maximum Offset

The termination must fall within the shaded
area shown in the chart. Use the indicated
restrictor position.

If using offsets, use the table below to
calculate the vertical rise and horizontal
offset

Offset
Length

Horizontal
Offset

Vertical

Rise

Offset Length

Hor. Offset

Vert. Rise

None

5" (125 mm)

1' (300 mm)

1' Section

1' (300 mm)

1' 7" (480 mm

2' Section

1' 9" (530 mm)

2' 4" (710 mm

3' Section

2' 5" (740 mm)

3' (915 mm)

4' Section

3' 2" (965 mm)

3' 8" (1.12 M)

4' + 1' Section

3' 9" (1.14 M)

4' 4" (1.32 M)

4' + 2' Section

4' 6" (1.37 M)

5' (1.52 M)

4' + 3' Section

5' 2" (1.57 M)

5' 9" (1.75 M)

5 feet

(1.5 M)

10 feet

(3 M)

(min.)

15 feet

(4.6 M)

20 feet

(6 M)

25 feet

(7.5 M)

30 feet

(9.1 M)

0 feet

33' (max)

(10 M)

0 feet

3 feet

(0.9 M)

6' (max)

(1.8 M)

5 feet
(1.5 M)

0 feet

0 feet

Restrictor

Position # 5

The maximum

offset lengths is

two 4' sections.

NOTE:

Restrictor positions

are based upon lab

tests. The ideal

restrictor position

may vary slightly,

especially when the

termination is near

a demarkation line.

Restrictor

Position # 7

Do not place an

offset directly off the

top of the heater.

3 feet

(0.9 M)

6' (max)

(1.8 M)

10 feet
(3 M)
(min.)

15 feet
(4.6 M)

20 feet
(6 M)

25 feet
(7.5 M)

30 feet
(9.1 M)

33' (max)
(10 M)