Installation, Packing list, Additional items required – Avalon Firestyles 564 SS Gas Installation User Manual
Page 7: Installation overview, Recommended installation procedure, For qualified installers only)

Installation
(for qualified installers only)
7
© Travis Industries
4 0 7 0 6 2 0
100-01188_000
Packing List
•
Propane Conversion Kit
•
Log Set
•
Wall Switch with Wire (see page
21 for details)
•
Firestop (sku 250-00747)
Additional Items Required
•
Direct Vent
•
Gas Line Equipment (shutoff valve, pipe, etc.)
•
Electrical Equipment (min. 14 gauge, grounded line)
Installation Overview
•
All requirements below must be met.
See the section
"Approved Vent
Configurations"
See the section
"Electrical Connection"
See the section
"Mantel Requirements"
Insulation must not fill
the 1/2" clearance
around the back and
sides of the fireplace.
See the section
"Vent Requirements"
See the section "Minimum
Framing Dimensions"
Drywall
Top Vent
Configuration
Rear Vent
Configuration
See the section
"Gas Line Installation"
1" Min.
Side
Wall
See "Optional Non-
Combustible Facing"
Drywall
See "Optional Non-
Combustible Hearth"
Nailing Brackets
Required Travis
Firestop (sku
250-00747)
Recommended Installation Procedure
1
Frame the opening for the fireplace. Make sure to allow for vent installation.
2
This fireplace is designed to accommodate 1/2" or 5/8" drywall (see "Nailing Brackets" on page 15
for details). Secure the fireplace to the framing.
3
Install the vent, gas line and electrical hook-up.
4
Install the wall switch (see page 21) or thermostat (if applicable).
5
Install the drywall.
6
Install the hearth (if applicable).
7
Install the facing (if applicable).
8
Install the mantel (if applicable).
9
Finalize the installation (see page 44) and install the grill or face.