6 2 optional equipment, For qualified installers only) – Avalon Firestyles 564 SS Gas Installation User Manual
Page 62

6 2
Optional Equipment
(for qualified installers only)
Travis Industries
4 0 7 0 6 2 0
100-01188_000
3.
Attach the wiring and rheostat assembly following the directions below.
N O T E
: You may need to cut or adjust some of the lock ties on the wiring harness.
N O T E
: Make sure wiring does not contact blower impellers or any hot surfaces. Use lock-ties if
necessary.
SNAP DISC
BL
OWER
Attach one black and
white wire to each
blower (orientation does
not matter).
Attach the wires labeled
SNAP DISC to the
snap disc (orientation
does not matter).
These wires are for the optional
remote control. Place them behind
the gas control valve.
Plug the power cord into the
receptacle at the rear of the fireplace.
VALVE-RED/BRN
SOLENOID
-BLU
Attach the rheostat assembly to the
fireplace with the two black screws.
4.
Turn on power to the fireplace.
N O T E
: To test the blower without turning on the fireplace, use a jumper wire to connect the two snap
wires together (turn off power prior to connecting the jumper wire).