Installation
(for qualified installers only)
Travis Industries
4 0 7 0 6 2 0
100-01188_000
Electrical Connection (required)
•
The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified
installer and must meet all local codes.
•
Make sure the household breaker is shut off prior to working on any electrical lines.
•
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.1.
•
The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)
Caution
: Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Left Side of Fireplace
Junction Box Assembly
Grounded 110V
Power Supply
Grounded Receptacle
Receptacle Cover Plate
Strain Relief