5 8 finalizing the installation – Avalon Firestyles 564 SS Gas Installation User Manual
Page 58
5 8
Finalizing the Installation
(for qualified installers only)
Travis Industries
4 0 7 0 6 2 0
100-01188_000
7
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve. Check the pilot. Adjust if necessary.
WARNING
:
When lighting or re-lighting the pilot, the glass must be removed (see page 44).
Standard
Screwdriver
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.