Installation, Mantel requirements – Avalon Firestyles 564 SS Gas Installation User Manual
Page 41
![background image](https://www.manualsdir.com/files/772733/content/doc041.png)
Installation
(for qualified installers only)
4 1
© Travis Industries
4 0 7 0 6 2 0
100-01188_000
Mantel Requirements
•
The illustration below details mantel clearances and maximum mantel depth.
•
Any material that protrudes more than 3/4” from the non-combustible facing is considered a mantel
and must meet the mantel requirements.
Mantel (combustilbe or non-combustible)
Combustible mantel columns (legs) that
protrude more than 3/4” from the glass
frame must meet the sidewall clearance (1”).
If they protrude 3/4” or less, they may be
placed directly to the side (but not in front) of
the fireplace.
Non-combustible mantel columns do not
have a minimum clearance.
38-1/2”
12”
Maximum