About external control – Audio Enhancement Product Manual User Manual
Page 45

Serial Transmission Terminal
Innovator
Cable
RXD
TXD
GND
Personal computer
or AV controller
About External Control
Cable Type: Cross
Maximum Cable Length: Less than 15 m (40 ft) .
Information about connectors
Notes:
• Contact your local representative for additional information on controlling the
Innovator from the computer via the RS-232 input .
The audio levels of the Innovator can be controlled remotely by connecting it to a personal
computer via a serial port . The microphone levels can be controlled independently; the
auxiliary inputs are controlled as a single mixed signal .
About Connections
Connect the CAE-100 Watt and the personal computer with a cable as shown in the diagram
below .
Serial transmission connection (RS-232) specifications
The Innovator specifications are shown below .
Signal Level
Contents
Description
Sync method
Asynchronous
Synchronizes every 1
character (8 bits)
Baud rate
9600 bps
Data transfer speed
Parity
None
Error detection
method
Character length
8 bits
Number of bit com-
posing 1 character
Stop bit
1 bit
Uses stop bit when
asynchronous
method
PIN
NAME
PIN
NAME
1
N .C . (DCD)
6
N .C (DSR)
2
RXD
7
N . C . (RTS)
3
TXD
8
N . C . (CTS)
4
N .C . (DTR)
9
N .C . (RI)
5
GND
---
○ ○
1
6
7
8
9
2
3
4
5
○ ○
○ ○
○ ○
○
45