Installation, Eds-07 – Audio Enhancement Product Manual User Manual
Page 42

42
Coaxial cable
:D
AE-DCF
EDS-07
Coaxial cable
:A
Coaxial cable
:B
Coaxial cable
:E
Infrared sensor connector
Coaxial cable
:
The following types and lengths of coaxial cables are recommended:
Use the following lengths and types of coaxial cables to connect the main unit and the sensors .
Coaxial cable length . . . . . . . . . . . . Less than 300'
Coaxial cable type . . . . . . . . . . . . . . . . RG6
When using the “AE-DCF” sensor coupler
Keep the total length of coaxial cable from the main unit to the coupler “coaxial cable length:
A” and from the coupler to each sensor “coaxial cable length: B to E” within a range of 300 ft .
[Caution]
Keep the differences of the length among cables from AE-DCF to EDS-07 (among cables B to E)
less than 36 ft .
Installation
Coaxial Cable: E
Coaxial Cable: D
Coaxial Cable: C
Coaxial Cable: B
Coaxial Cable: A
EDS-07