Part 1 [Good example]:
Coaxial cable length: If A = 120', B = 24', C = 12', D = 18', E = 30'
[Results]
Coaxial cable: B to E are less than 36', and the cable length of
“A: 120' + E: 30' = 150' ”, therefore,
there is no problem with cable lengths . (It is within a range of 300' .)
Part 2 [Good example]:
Coaxial cable length: If A = 180', B = 90', C = 105', D = 75', E = 99'
[Results]
Coaxial cable: the length of cables B to E:
“(maximum:105')–(minimum:75') = 30' ”, therefore,
there is no problem with cable length . (It is within a range of 36' .)
The cable length of
“A: 180' + C: 105' = 285' ”, therefore, there is no problem with cable length .
(It is within a range of 300' . )
Part 3 [Bad example]:
Coaxial cable length: If A = 150', B = 120', C = 135', D = 150', E = 165'
[Results]
Coaxial cable: the length of cables B to E:
“(maximum:165')–(minimum:120') = 45' ”, therefore,
there is a problem with cable length . (It is over the range of 36' .)
The cable length of
“A: 150' +E: 165' = 315' ”; therefore, there is a problem with cable length .
(It is over the range of 300') .