Setting the pa aux mute on the innovator – Audio Enhancement Product Manual User Manual
Page 30
30
Setting the PA
Aux Mute on the Innovator
Caution:
Wiring for the PA Input are fixed to the screw terminals . The torque for the screws is 0 .98
N. m } 0 .1 N. m (10 kgf. cm }1 kgf. cm) .
Be sure to switch the amplifier off before connecting the wires . Carefully check the polarities
before connecting it . Connection to the wrong polarity may prevent the amplifier from
functioning correctly .
The mute function works as shown:
Volume
Auxiliary input level
Screw terminals
Auxiliary input
levels reduced by 12 dB
Muting of auxiliary input
Mute finished
when input is
turned off
Auxiliary input volume
returns to original level
after approximately 10
seconds
Time
This manual is related to the following products: