IPMI Functions List

RTM-ATCA-736X-DD Installation and Use (6806800L82C)

65

5.5

Communication Mechanisms for Disk Extraction

The RTM includes two disk eject request buttons located on the RTM panel. When pressed, the
behavior of the RTM is governed by the state of jumper identified as HDR500. The diagram
below shows the location of the eject buttons and header.

Disk eject behavior differs by the position of jumper HDR500.This table defines the operations
that take place when the drive eject request button is depressed.

Figure 5-1

Locations of Disk Eject Jumper and Disk Eject Buttons

Table 5-9 Disk Eject jumper Position vs. Function

Jumper/Header
(HDR500)

Extraction Type

Description

None

Slave

In this configuration, the host blade must grant
the RTM explicit permission for drive removal.
This permission is conducted using custom
commands exchanged between the MMC on the
RTM and the Host.

1-2