Table 4-2 Environmental Specifications for the RTM-ATCA-736X-DD
Specification
RTM with rotating SAS Disk Media
Installed
RTM without Disks
Operating Voltage
+12V +/- 5% (payload power)
+12V +/- 5% (payload power)
Operating Temperature (normal)
+5°C to +40°C
+0°C to +49°C
Operating Temperature (short term) -5°C to +55°C (Consult disk drive
manufacturer for warranty
implications)
+0°C to 70°C
Storage Temperature
-40 °C to 70°C
-40 °C to 100°C
Operating Temperature Gradient
11°C /H (max)
11°C /H (max)
Storage Temperature Gradient
20°C /H (max)
20°C /H (max)
Shipping Temperature Gradient
20°C /H (max) *1
20°C /H (max)
Operating Humidity
5% to 85% (non condensing)
5% to 90% (non condensing)
Storage Humidity
5% to 90% (non condensing)
5% to 90% (non condensing)
Shipping Humidity
5% to 90% (non condensing)
No condensation
Condensation
No condensation
No condensation
Altitude, operating (relative to sea
level)
-305 to +3,048 m (-1000 to +10,000
feet)
(-1000 to +40,000 feet)
Altitude, non-operating (relative to
sea level)
-305 to +12,192 m (-1000 to
+40,000 feet)
(-1000 to +40,000 feet)
Shock, operating
980 m/s2 (100G) / 1 ms duration
500G / 0.5msec duration
Shock, non-operating
3,920 m/s2 (400G) / 1 ms duration
1000G / 0.5msec duration
Vibration, operating
0.6 mm (5 to 20Hz) / 9.8 m/s2 (1G)
(20 to 300Hz) or less Note: At
random seek write/read and default
on retry setting with log sweep
vibration.
2.17 GRMS (5-700Hz)