3 requirements, 1 environmental requirements, Table 2-2 – Artesyn MVME7100ET Single Board Computer Installation and Use (June 2014) User Manual
Page 27: Mvme7100et specifications, Table "mvme7100et, Hardware preparation and installation

Hardware Preparation and Installation
MVME7100ET Single Board Computer Installation and Use (6806800K87E)
27
2.3
Requirements
Make sure that the board, when operated in your particular system configuration, meets the 
requirements specified in the next sections.
2.3.1
Environmental Requirements
The following table lists the currently available specifications for the environmental 
characteristics of the MVME7100ET. A complete functional description of the MVME7100ET 
baseboard appears in 
Chapter 4, Functional Description
.
Operating temperatures refer to the temperature of the air circulating around the board and 
not to the component temperature.
Table 2-2 MVME7100ET Specifications
Characteristics
Operating
Cooling Method
Forced air
Operating temperature
-40 C to 71 C (-40 F to 160 F)
Storage Temperature
-50c to +100c
Temperature Transition Time
Operational temperature transition 
rate 0.5c/minute
Vibration
Swept sine: 1.0 g from 5.0 to 200 Hz 
Sweep rate: 0.25 octaves/minute
Humidity
Designed to operate up to 100% 
relative humidity, Non condensing
The RTC field removable battery should be removed, if MVME7100ET has to be stored beyond 
its operational temperature range.