2 image flags, Table 6-2, Motload image flags – Artesyn MVME7100ET Single Board Computer Installation and Use (June 2014) User Manual
Page 108: Motload firmware
MOTLoad Firmware
MVME7100ET Single Board Computer Installation and Use (6806800K87E)
108
6.7.2
Image Flags
The image flags of the header define various bit options that control how the image will be
executed.
COPY_TO_RAM
If set, this flag indicates that the image is to be copied to RAM at the address specified in
the header before control is passed. If not set, the image will be executed in flash. In both
instances, control will be passed at the image offset specified in the header from the base
of the image.
IMAGE_MCG
If set, this flag defines the image as being an Alternate MOTLoad, as opposed to USER,
image. This bit should not be set by developers of alternate boot images.
IMAGE_POST
If set, this flag defines the image as being a power-on self-test image. This bit flag is used
to indicate that the image is a diagnostic and should be run prior to running either USER or
MCG boot images. POST images are expected, but not required, to return to the boot
block code upon completion.
Table 6-2 MOTLoad Image Flags
Name
Value
Interpretation
COPY_TO_RAM
0x00000001
Copy image to RAM at ImageRamAddress before
execution
IMAGE_MCG
0x00000002
Alternate MOTLoad image
IMAGE_POST
0x00000004
POST image
DONT_AUTO_RUN
0x00000008
Image not to be executed