You must make sure that the board, when operated in your particular system configuration,
meets the environmental requirements specified below.

Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.

Product Damage
High humidity and condensation on surfaces cause short circuits.
Do not operate the system outside the specified environmental limits. Make sure the
product is completely dry and there is no moisture on any surface before applying power.

Table 2-1 Environmental Requirements

Requirement

Operating

Non-Operating

Cooling Method

Forced-Air

Temp Cycle Class

-40°C–85°C:500cyc

Temperature

0°C–55°C

-40 °C - 85 °C

Humidity

10 -90% Non-condensing

-

Vibration

0.01g ^2/Hz at 5-500 Hz
Random Vibration

Shock

20 g 11 ms sine or saw

-

Altitude

-60–4000 m ASL