Remote, Setremotebaud, Getremotebaud – Argox PA-20 Programming Guide User Manual
Page 96

PT-20 Programming Guide
94
Purpose: Setting the RemoteLink baud rate.
Syntax: void SetRemoteBaud(int slBaud);
Example call: SetRemoteBaud (0);
Includes:
#include “SDK.h ”
Description: This function can set RemoteLink baud rate(when use com port), the baud
rate setting as follows:
slBaud
Baud rate(bps)
0
115200
1
57600
2
38400
3
19200
4
9600
5
4800
Returns: None
Purpose: Getting the RemoteLink baud rate.
Syntax: int GetRemoteBaud(void);
Example call: Switch(GetRemoteBaud())
{
Case 0:
_printf_color(COLOR_
RED, “RemoteLink baud rate=115200”);
Break;
Case 1:
_printf_color(COLOR_
RED, “RemoteLink baud rate=57600”);
Break;
Case 2:
_printf_color(COLOR_
RED, “RemoteLink baud rate=38400”);
Break;
Case 3:
_printf_color(COLOR_
RED, “RemoteLink baud rate=19200”);
Break;
Case 4:
_printf_color(COLOR_
RED, “RemoteLink baud rate=9600”);
Break;