Haltscanner1, Triggerstatus, Scanner_reset – Argox PA-20 Programming Guide User Manual
Page 26
PT-20 Programming Guide
24
Example call: InitScanner1( );
while(1)
{
if (Decode())
SleepScanner1(TRUE);
while(_getchar()==0);
SleepScanner1(FALSE);
}
Includes:
#include “SDK.h ”
Description: Use SleepScanner1 function to set scanner in sleep mode. You have not
to initial scanner again, and it would be scan again.
Returns: None
Purpose: Stop the scanner port from operating.
Syntax: void HaltScanner1(void);
Example call: HaltScanner1( );
Includes:
#include “SDK.h ”
Description: Use HaltScanner1 function to stop scanner port from operating. To
restart a halted scanner port, the initialization function, InitScanner1,
must be called. It is recommended that the scanner port should be
stopped if the barcode decoding is not required for a long period of time.
Returns: none
Purpose: To check the scan key status.
Syntax: int TriggerStatus(void);
Example call: if (TriggerStatus( ))
_printf_color(COLOR_
RED, “Scan key pressed!”);
Includes:
#include “SDK.h ”
Description: This function can check the scan key status, if pressed scan key, this
function will return 1, else will return 0.
Returns: 0:Scan key is not pressed.
1:Scan key is pressed.
Purpose: Set scanner setting to default.
Syntax: BOOL Scanner_Reset(void)
Example call: If (Scanner_Reset())
_printf_color(COLOR_
RED, “Scan module reset OK!”);
Includes:
#include “SDK.h ”