background image

PT-20 Programming Guide

127

Note1:

There are seven bar code lock lengths available. Specific code type can be assigned to

a lock length.

Code type:

Hex

CODE11

64

CODE39

65

CODE93

66

CODE128

67

CODABAR

68

INDUSTRIAL_25 6B

INTERLEAVED_25 6C

MSI_PLESSEY

6E

UK_PLESSEY

6F

TELEPEN

70

MATRIX_25

73

TRIOPTIC

7E

Length:

0~80 (0: Disable)

Default setting:

“0000”

Example:

Cmd1 Cmd2 Value
7 10 “670C”
7 11 “6514”

7 12 “6710”

Code 128: Can only read 12 or 16 the length of the barcode.