beautypg.com

2 over current, 3 over power, 4 over temperature – AMETEK SLH Series RevC User Manual

Page 52

background image

Operation

Sorensen SLH-Series DC High Power Electronic Load

3.10.2 Over Current

The protection point of over current protection (OCP) is preset in the load. The
activation values of the OCP circuit are shown in Table 3-3.

When an over-current condition occurs, the OCP circuit is activated, and the lower 5-
character monitor on the front panel of the electronic load flashes “oCP”. The load will
automatically go to a LOAD OFF state.

Once the over current condition is reset, the lower 5-character monitor will resume
normal operation.

3.10.3 Over Power

The protection point of over power protection (OPP) is preset in the load. The activation
values of the OPP circuit are shown in Table 3-3.

When an over-power condition occurs, the OPP circuit is activated, and the upper 5-
character monitor on the front panel of the electronic load flashes “oPP”. The load will
automatically go to a LOAD OFF state.

Once the over power condition is reset, the upper 5-character monitor will resume
normal operation.

3.10.4 Over Temperature

SLH-Series DC electronic loads also are designed with a temperature sensor(s) for over
temperature protection (OTP). The activation values are shown in Table 3-3.

When an over-temperature condition occurs, the OTP circuit is activated, and the lower
5-character monitor on the front panel of the electronic load flashes “otP”. The load will
automatically go to a LOAD OFF state.

When OTP occurs, please check the environment condition such as the ambient
temperature and distance between the rear panel of Electronic load mainframe and wall
is greater than 6in. / 15cm.

Once the over temperature condition is reset, the lower 5-character monitor will resume
normal operation.

Model OVP

OCP

OPP

OTP

SLH-60--120-600 63V 126A 630W 85

°C

SLH-60-120-1200 63V 126A 1260W 85

°C

SLH-60-120-1800 63V 126A 1890W 85

°C

SLH-60-240-1200 63V 252A 1260W 85

°C

SLH-60-240-1800 63V 252A 1890W 85

°C

SLH-60-360-1800 63V 378A 1890W 85

°C

Table 3-3 Summary of Over Protection Values

3-22

M540074-01