5 sequence function, Sequence function – AMETEK SLH Series RevC User Manual
Page 46
Operation
Sorensen SLH-Series DC High Power Electronic Load
3.5
SEQUENCE FUNCTION
There are two modes in the SEQUENCE function: EDIT MODE and TEST MODE, The AUTO SEQ
function can be initiated by pressing State 3 + State 4 keys simultaneously. To enter EDIT MODE,
press STORE; to enter the TEST MODE, press START key. Please refer to the flow chart in Figure
3-7. A brief description of each mode follows the flow chart.
Press
S3+S4 Buttons
Simultaneously
EDIT Seq or
RUN Seq
Press
BANK Up/Down
Keys to select
sequence number
Bank LED
Display
Start
EDIT
RUN
Press
START Button
Testing
Memory Bank
and State
under test
End?
Step = Step + 1
Exit?
Press
EXIT Button
Pass/Fail
Display GO
Display NG
YES
Test
sequence
number nx
NO
YES
NO
PASS
FAIL
Press Exit Key
GO / NG
1
1
Test sequence
number nx
Press
STORE Button
Step Number
Select Memory
Location: Press
Bank Up/Down,
State 1-5
Press STORE
Button
t1 test time,
when STORE
is released
Press BANK Up/
Down to select t1
time in 0.1sec
Press STORE
Button
t2 delay time,
when STORE
is released
Press BANK Up/
Down to select t2
time in 0.1sec
Press STORE
Button
Is Step=16 (F)
YES
End?
Step=Step+1
NO
NO
YES
Bank Number
Press
EXIT Button
Bank LED
Display
1
"t1" when
STORE button
is held
"t2" when
STORE button
is held
Figure 3-7 Auto Sequence Function Set-Up and Operation Flowchart
3-16
M540074-01
Rev C