6 initial setting of slh-series dc loads, Initial setting of slh-series dc loads – AMETEK SLH Series RevC User Manual
Page 48

Operation
Sorensen SLH-Series DC High Power Electronic Load
3.6
INITIAL SETTING OF SLH-SERIES DC LOADS
Table 3-1 lists the factory, or initial, load value settings when the SLH-series DC electronic load
is initially powered ON when it first arrives from the factory.
Item
SLH-60-120-600 SLH-60-120-1200 SLH-60-120-1800 SLH-60-240-1200
SLH-60—240-
1800
SLH-60-360-1800
Basic Settings
CC LOW
[amps]
0.0000 0.0000 0.000 0.0000 0.0000 0.0000
CC HIGH
[amps]
0.0000 0.0000 0.000 0.0000 0.0000 0.0000
CR HIGH
[
Ω]
1875.
1875.
1875.
937.5
937.5
625.0
CR LOW [
Ω]
1875.
1875.
1875.
937.5
937.5
625.0
CV HIGH
[volts]
60.00 60.00 60.00 60.00 60.00 60.00
CV LOW
[volts]
60.00 60.00 60.00 60.00 60.00 60.00
CP LOW
[watts]
0.000 0.000 0.000 0.000 0.000 0.000
CP HIGH
[watts]
0.000 0.000 0.000 0.000 0.000 0.000
Dynamic Settings
FALL [A/
μs]
0.5000 0.5000 0.5000 1.0000 1.0000 1.5000
RISE [A/
μs]
0.5000 0.5000 0.5000 1.0000 1.0000 1.5000
T
HIGH
[ms]
0.050 0.050 0.050 0.050 0.050 0.050
T
LOW
[ms] 0.050 0.050 0.050 0.050 0.050 0.050
Go/No Go Limits
V
HIGH 60.00 60.00 60.00 60.00 60.00 60.00
V
LOW 0.000 0.000 0.000 0.000 0.000 0.000
CURR.
HIGH
120.00 120.00 120.00 240.00 240.00 360.00
CURRENT
LOW
0.000 0.000 0.000 0.000 0.000 0.000
POWER
HIGH
600.00 1200.0 1800.0 1200.0 1800.0 1800.0
POWER
LOW
0.000 0.000 0.000 0.000 0.000 0.000
System Settings
V
SENSE Auto Auto Auto Auto Auto Auto
LD-ON
[volts]
1.0 1.0 1.0 1.0 1.0 1.0
LD-OFF
[volts]
0.500 0.500 0.500 0.500 0.500 0.500
Table 3-1 SLH-Series DC Electronic Load Factory Settings for Power On
3-18
M540074-01
Rev C