Elgar CW-M Series

4-2

M161570-01

Table 4

–1. CONFIG Dipswitch Functions

Switch

Position

Function

1,2

ON

Required to enable current master and slave operation

OFF

Stand-alone unit or phase slave

3

ON

Current slave

OFF

Current master

4

ON

Phase slave

OFF

Phase master

5

ON

Output disabled at power-up, Fault LED lit

Note: If the output switch is in the ON position at power-up,
it has to be moved to the OFF/RESET position, then back
to the ON position to enable the output

OFF

Output enabled at power-up

6

–7

Reserved for future expansion

8

ON

Constant Current mode

OFF

Current Shut-off (fault) mode

9

–12

Phase angle selections (see Table 4

–2 on page 4-8)

4.2 SETTING THE CONFIG DIPSWITCH

You may change the CONFIG dipswitch settings to change the default
characteristics of the unit as follows:

If you would like the power supply to turn its output off, and generate a fault
indication if its output current ever reaches the level that you set from the
front panel, then set switch 8 to the off position.

1 2 3 4 5 6 7 8 9

10 11 12

ON

OFF

Figure 4-3. Dipswitch Default Setting, Example 1

To set the power supply to always start up at OV (fault mode) each time
that power is applied, set switch 5 to the on position.

1 2 3 4 5 6 7 8 9

10 11 12

ON

OFF

Figure 4-4. Dipswitch Default Setting, Example 2