beautypg.com

Rear panel connections -4, Input -4, 5 rear panel connections – AMETEK CW-M User Manual

Page 14: 6 input

background image

Elgar CW-M Series

2-4

M161570-01

2.5 REAR PANEL CONNECTIONS

Input Connector: Covered barrier terminal strip with strain relief

Output Connector: Covered barrier terminal strip with strain relief

Remote output voltage sense: 5 VRMS max total lead voltage drop

Remote Analog Control:

Output voltage control 0 to 5 VDC
Output frequency control 0 to 5 VDC (max slew rate 5V/second)

Dip Switches (see Section SECTION 4 on page 4-1):

Master or Slave field configuration

Output disable/enable at power-up

Overcurrent shutdown enable/disable

2.6 INPUT

Voltage and Frequency

CW 801M: 90 to 264 VAC, 47 to 63 Hz, single-phase

CW 1251M: 103 to 264 VAC, 47 to 63 Hz, single-phase

CW 2501M: 180 to 264 VAC, 47 to 63 Hz, single-phase

Neutral should be connected to ground at building entrance

Max neutral to chassis voltage: 132V RMS

Current

CW 801M: 13 ARMS max

CW 1251M: 18.5 ARMS max

CW 2501M: 19.5 ARMS max

Power Factor

>0.95 at full load nominal line

Efficiency

>70% at full load