Installation -1, Unpacking -1, Installation – AMETEK CW-M User Manual
Page 17: 1 unpacking

M161570-01
3-1
SECTION 3
INSTALLATION
The Elgar CW series power supply has been fully calibrated and tested
prior to shipment. The instrument is ready for immediate use upon
receipt.
CAUTION! The CW unit weighs from 48 to 86 lbs. (22 to 40 kg),
depending on the model. A two
–person lift is recommended.
WARNING! Hazardous voltages are present when operating this equip-
ment. Please read the Safety Notice at the beginning of this manual prior
to installation, operation, or maintenance.
3.1 UNPACKING
Perform a visual inspection of the shipping container prior to accepting the
package from the carrier. If extensive damage to the shipping container is
evident, a description of the damage should be noted on the carrier's
receipt and signed by the driver of the carrier agent.
Perform a visual inspection of the instrument when it is removed from the
shipping container. Check for shipping damage such as dents, scratches,
distortion, and damaged connectors.
If damage is not apparent until the instrument is unpacked, a claim for
concealed damage should be placed with the carrier. In addition, the
shipping container(s) and filler material should be saved for inspection.
Forward a report of damage to the Elgar Service Department. Elgar will