beautypg.com

Adtec digital EN-91 / EN-91P (version 1.02.29) Manual User Manual

Page 25

background image

depends on mode selected.

If MPEG 1 Layer 2, the available rates
are 32, 48, 56, 64, 80, 96, 112, 128,

160, 192*, 224, 256, 320, 384
kBits/sec .

If Dolby Digital AC3, the available

rates are 56, 64, 80, 96, 112, 128,
160, 192*, 224, 256, 320, 384, 448,

512, 576, 640 kBits/sec.

Note: * For MPEG 1 Layer 2 and Dolby
Digital AC3, the recommended lowest

rate for professional applications is
192 kBits/sec.

In Dolby-E mode, do not set this value.

The bitrate will be auto-detected.

Level

Controls the volume level in dBs

user-defined using the numeric

keypad
range = -18 dBs to 8 dBs in

increments of 1

Analog

Audio Level

Control the volume level -15 to

+15 (dBs) in 1 dB increments for
AUDIO 1 and 2 only

This trims the level on the analog

audio path (only) to accomodate
external audio gear variability.

Sync

Audio Sync sets the audio sync
offset. This measurement is in

milliseconds, and works only on
analog audios.

+/- 800

Musicam
Mode

Allows the operator to choose how
to encode left and right analog

audio inputs.

STEREO
MONO

DUALMONO

IFB

This is a low latency audio path

for communications to a remote
van or studio using the same

distribution path. It requires a
special IFB receiver or manual PID

selection with a standard IRD.
Note: There is no PID reference in

the PMT for this functionality. It is
considered a ghost PID. It is also

not lip-sync aligned with video.

OFF

ON
GHOST

SDI Pair

Allows the operator to route

embedded audio from SDI input to
the specified audio encoder.

user-defined