beautypg.com

Connecting the drives – Adept SmartMotion User Manual

Page 36

background image

Chapter 2 - System Installation

36

Adept SmartMotion Installation Guide, Rev. C

Connecting the Drives

Each channel (1 to 6) has a 9-pin female D-connector that connects to the user’s
equipment. All six connectors have the same pin assignments (see

Table 2-4 on page 34

).

Refer to

Figure 2-6

for the physical location of each connector. All signal nomenclature is

defined as viewed from the controller. Thus, an output is controlled by the Adept
controller and an input is monitored by the Adept controller.

Table 2-7. MP6-S Connector Pin Assignments (Typical, 1 of 6)

Pin

Signal

Abbrev.

Description

Signal

Type

Mode of Operation

1

DE+

Drive Enable (+)

output

Not configurable –
On to enable drive

2

DE–

Drive Enable (return)

return

4

DF+

Drive Fault (+)

input

Configurable using
SPEC program

5

DF–

Drive Fault (return)

return

7

CD+

DAC Command (+)

output

±10V, configurable
using SPEC program

8

CD–

DAC Command (return)

return

3

SHD

Shield

a

a

If two separate cables are used for Command signals and Drive signals, then their shields
should be tied together at Pin 3 SHD.

shield

——

6

Not connected

9

Not connected