C50 ICEBOX
U
SER
'
S
M
ANUAL
Electrical
Safeguards
WARNING:
Follow the precautions listed below to avoid permanent damage to the emulator.
If the target application board has its own power supply, follow the power-up and power-
down procedures in the precise order shown below
1
:
I.
Always use a grounding strap to prevent damage resulting from electrostatic
discharge (ESD)
II. Power-Up Precautions
1. Remove V
CC
jumper J1
2. Power-up the emulator
2
3. Depress the emulator RESET button
4. Connect the target pod to the target application
3
5. Power-up the target application (if any)
III. Power-Down Precautions
When powering down, follow this procedure in the precise order shown below:
1. Depress the RESET button on the emulator
2. Power-down the target application board (if any)
3. Remove the target pod
4. Power-down the emulator
Notes:
1. Refer to the "Precaution List" section in Chapter 5 for additional operating precautions
specific to various devices.
2. Do not leave the emulator powered up with the RS-232 cable connected to a powered-
down PC.
3. Before inserting target pod into target application board, refer to Chapter 2 to determine
appropriate jumper selections and options.
UM009701-0201