Control Interface Operation
The Control Interface is normally LOCKED.
To UNLOCK, hold ESC and OK together for 5 seconds.
You are now in the CONTROL MENU
Use to scroll up and down the menu.
Press OK to enter a menu item
Use to set the item parameter, or to scroll to the next menu level.
Use ESC to go BACK, and OK to confirm settings (
).
To LOCK, hold ESC for 5 seconds.
Menu will time out after ten minutes.
The Control Menu
SET DMX OPTIONS
SET DMX MODE
This menu item allows the user to check (and if necessary change) the DMX/RDM mode.
BASIC
Standalone operation, no DMX/RDM (factory default)
MONITOR
Standalone, plus support for RDM remote configuration and monitoring
CONTROL
Monitor, plus use of a single DMX address to control Lamp relay
SERVICE
Monitor, plus use of three DMX slots to control Lamp, heater and fan
Important: Please ensure that the DEC3.2 is NOT left in Service Mode.
SET DMX ADDRESS (in Monitor, DMX or Service modes)
Select a DMX starting address in the range 001 to 510
1 – Lamp Relay
In Service Mode an addition two slots are available
2 – Fan Relay
3 – Heater Relay
Note that the DMX control is designed using a SAFETY pile-on Logic. So the DMX
input can only override automatic settings in a safe manner.