Control interface – Tempest TornadoRetrofit Kits User Manual
Page 23

Tornado Enclosure User Manual
page 23
Control Interface
LED Indicators
Heater
SHORT PULSES
(green)
Lamp is off
Temperature is normal
Heater is pulsing to prevent condensation
ON (Green)
Temperature is LOW
Heater is ON
OFF
Lamp is on
Temperature is normal
Fan
PULSES
(green)
Lamp is off
Temperature is normal
Fan is moving small amount of air to prevent
condensation
ON (Green)
Lamp is ON, or
Temperature is HIGH
Fan is cooling enclosure
Lamp On
ON (Green)
Current sensing shows lamp is ON
Lamp hour counter is running
OFF
Current sensing shows lamp is OFF
Lamp hour counter is not running
Lamp Relay
ON (Green)
Lamp relay is closed (normal)
Luminaire power receptacle is energized
OFF
Lamp relay open (due to overtemp or DMX
control). Luminaire is electrically isolated
Temp
ON (Green)
Temperature is in normal range
ON (Red)
Temperature is above Top setting, or below
bottom setting
FLASHING (Red)
Temperature is above Cutoff level
Luminaire power is isolated
DMX
OFF
DEC3.2 is in BASIC Mode – DMX not used
ON (GREEN)
Good DMX or RDM data packet received.
ON (RED)
Control Mode: DMX Fail
Monitor Mode: No RDM information being
received (this is normal)