Operating modes – Tempest TornadoRetrofit Kits User Manual
Page 19

Tornado Enclosure User Manual
page 19
Operating Modes
DEC3.2 may operate in one of four modes, set using either the Front Panel or by RDM control. In
all configurations, the luminaire inside the enclosure may also be an RDM enabled device.
Basic Mode (factory setting)
Standard temperature settings
DMX and RDM disabled
Best for standalone operation
Monitor Mode
As Basic mode, plus:
RDM status reporting
RDM configuration – settings may be changed remotely or at the enclosure control
panel
DEC3.2 does not require a DMX signal to operate
Control Mode
As Basic mode, plus:
Enclosure functions as a 1-channel DMX device, with remote control of the lamp relay
o
DMX level > 75% enables normal relay operation (normally ON)
o
DMX level < 25% disables normal relay operation (relay turns OFF)
o
This allows you to force a hard reset of the lamp relay in the event of a
luminaire malfunction
Control mode is recommended for show control applications, but can be risky in live
show operation.
Service Mode
For trained service personnel only
Normal operation is suspended and the enclosure functions as a 3-channel DMX
device:
o
Lamp Relay
o
Fans
o
Heater
Service mode is ONLY for troubleshooting – DO NOT use Service mode for normal
operation.