Wiring and Control
All electrical work must be carried out by a properly licensed electrician, in compliance
with local electrical standards. Failure to observe this point will void the factory
warranty for the Tempest Enclosure.
1
Switch off power to the branch circuit, carefully following lockout and tag-out procedures.
Failure to do so could cause serious injury or death.
2
You will need two electrical junction boxes, located within a short distance from the
enclosure, one for power, one for DMX control. Use outdoor-rated flexible conduit between
the box and the enclosure.
3
AC and control circuits must be wired in separate conduits.
Conduit entry holes
Power and DMX conduit entries
The conduit entry holes accept US ½” conduit fittings, and
international 20-22mm (OD) conduit fittings.
AC
Power
DMX
Control
Flexible Conduit
120VAC,
or
208VAC
or
230VAC
Lighting
Control
AC Power
DMX Control
Ø 0.875”
22.2mm