beautypg.com

Dec3.2 main functions, Factory settings – basic mode – Tempest TornadoRetrofit Kits User Manual

Page 18

background image



Tornado Enclosure User Manual

page 18

DEC3.2 Main Functions

1 Sense current to luminaire (lamp on/off)
2 Record lamp hours

3 Monitor temperature and humidity inside Enclosure
4 Maintain temperature at safe operating level

5 Prevent condensation
6 Isolate luminaire in case of unsafe temperature

7 Report status over RDM
8 (Optional) remote luminaire relay control over DMX

DEC3.2’s function depends on whether the luminaire lamp is on or off:

Lamp ON

Fans on

Heater off

Monitor temperature and humidity

Isolate luminaire power if temperature exceeds max limit

Record lamp hours

Lamp OFF

Monitor temperature and humidity

o

If temp below bottom setting, run heater

o

If temp above top setting, run fans

o

If temp in normal range, run anti-condensation routine

Factory Settings – Basic Mode

In most applications, DEC3.2 will operate correctly with its factory default settings, in Basic

operating mode.

You do not need to do anything. Please skip to the Power Connections section below.

If your needs are more complex, read on.