DEC3.2 Control Parameters
Temperature Settings:
Cutoff Temp
Range 0-15°C, Default = 15°C
Top Set
Range 35-45°C, Default = 40°C
Bottom Set
Range 0-10°C, Default = 10°C
Notes:
1 The Cutoff Temperature is an incremental temperature range above the Top
Set temperature. So the default 15°C cutoff and 40°C Top Set means that the
lamp relay will open when a temperature of 55°C is reached.
2 In moving light enclosures the temperature sensor is located in the exhaust
airflow. Temperatures shown may be higher than those around the luminaire.
3 We recommend using the factory default settings for several weeks or
months before making any changes. In most cases they will not be necessary.
Humidity
Range 50-90%, Default 80%
The threshold at which incoming air is more aggressively heated to remove
moisture.
DMX Address Range 001-510, Default 001
Sets the DMX address for the lamp relay control.
Fan Overrun
Range 1-15 minutes, Default 5 minutes
Time that the enclosure fan(s) will run after the fixture/projector lamp is turned
off.
Temp C/F
Display Degrees Celsius or Fahrenheit. Default Celsius
Note that temperature settings must always be Celsius.
Lamp Hours
Default 0000
Counts lamp hours – you must reset to zero when changing lamps.
Over-temperature Warning, Fans on
Normal operation
Under-temperature Warning, Heater on, Fans off
Lamp relay open – Lamp OFF