beautypg.com

Camera settings (advanced) cont, Auto exposure configuration, P-iris control – NEXCOM NCr-302-VHR User Manual

Page 54: Ir cut filter (icr) control

background image

Copyright © 2013 NEXCOM International Co., Ltd. All Rights Reserved.

44

Chapter 2: Camera Configuration

NCr-302-VHR User Manual

Auto Exposure Configuration

Maximum Exposure Time

Specifies the maximum exposure time when operating in Auto Exposure
mode, the range is 1/7 ~ 1/1000, with 1/1000 being the shortest exposure
length.

Maximum Sens Up Gain

Specifies the maximum gain when operating in Auto Exposure mode, the
range is 1 ~ 512, with 1 being the lowest gain.

P-Iris Control

Auto

When enabled, the P-Iris will adjust the opening automatically based on the
lighting levels in the environment.

Manual

Adjust the opening of the iris manually in the range of 0 ~ 100, with 0 being
the smallest value.

IR Cut Filter (ICR) Control

Auto

When enabled, the camera will automatically turn the infrared lights on or
off based on the lighting levels in the environment.

Day Mode

Enables day mode and turns the IR cut filter control off.

Night Mode

Enables night mode and turns the IR cut filter control on.

Camera Settings (Advanced) Cont.