beautypg.com

B: p, Ppendix, Ower – NEXCOM MPPC 2120T User Manual

Page 113: Onsumption

background image

Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.

97

MPPC 2120T/3220T User Manual

Appendix B: Power Consumption

a

PPendix

B: P

oWer

C

onsumPtion

Power Consumption Measurement

Purpose
The purpose of the power consumption test is to verify the power dissipa-
tion of the system and the load of the power supply.

Test Equipment
1. PROVA CM-07 AC/DC CLAMP METER
2. Burn-in test ver: 2.0

Device Under Test
DUT: Sys #1

Test Procedure
1. Power up the DUT and then boot Windows XP.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Measure the power consumption and record it.

MPPC 2120T

+12V

+24V

+30V

Full-Loading Mode

4.14A

2.09A

1.68A

Total

49.68W

50.16W

50.4W

Standby Mode

0.92A

0.48A

0.39A

Total

11.04W

11.52W

11.7W

MPPC 3220T

+24V

Full-Loading Mode

2.72A

Total

65.28W

Standby Mode

0.56A

Total

13.44W

This manual is related to the following products: