20

50

100

500

1000

5000

10000

20000

-24

-12

-3

0

10

20

Frequency in [Hz]

P

o

w

e

r

in

[

d

B

]

FilterType = 'LowP' (Lowpass) Freq = 1000Hz

Q = 0.707 (default) Butterworth 2.Ordnung

You can choose between a high pass filter 1st or 2nd order. The Q of a 1st order high pass
filter is always fixed. At a 2nd order high pass filter Q is adjustable in steps of 0.001 from 0.2
to 20.

The parameter 'Gain' has no effect with the low pass filters.

Examples of how to set up low pass filters and how many parameteric filters are necessary,
are listed in following table.

Type of
filter

Slope

Number

of

necessary

PEQs

Q

high- /

low

pass

filter 1

Q

high- /

low

pass

filter 2

Q

high- /

low

pass

filter 3

Q

high- /

low

pass

filter 3

Butterworth
1st ord.

6 dB/

oct.

1

0.707

1st

order

-

-

-

Butterworth
2nd ord.

12 dB/

oct.

1

0.707

2nd

order

-

-

-

Linkwitz-
Riley
2nd ord.

12 dB/

oct.

1

0.5

-

-

-

Butterworth
3rd ord.

18 dB/

oct.

2

1

0.707

1st

order

-

-

Butterworth
4th ord.

24 dB/

oct.

2

1.307

0.541

-

-

Linkwitz-
Riley
4th ord

24 dB/

oct.

2

0.707

2nd

order

0.707

2nd

order

-

-

Butterworth
5th ord.

30 dB/

oct.

3

1.618

0.618

0.707

1st

order

-

Butterworth
6th ord.

36 dB/

oct.

3

1.932

0.707

0.518

-

Linkwitz-
Riley
6th ord.

36 dB/

oct.

3

1

1

0.5

-