You can select the following options for every GPO:
Setting
Option
Description
low / open
always 0V
always
high / closed
always 5V
low / open
0 V, switched on amplifier
power on
high / closed
5 V, switched on amplifier
low / open
0 V, switched on amplifier signal paths ready for
operation
system ready
high / closed
5 V, switched on amplifier signal paths ready for
operation
low / open
0 V, when channel 1 is muted
Mute CH1
high / closed
5 V, when channel 1 is muted
low / open
0 V, when channel 2 is muted
Mute CH2
high / closed
5 V, when channel 2 is muted
low / open
0 V, when channel 1 and 2 are muted
Mute CH1+2
high / closed
5 V, when channel 1 and 2 are muted
low / open
AES/EBU input is activated, otherwise analog input
AES-EBU/
Analog
high / closed
AES/EBU input is activated, otherwise analog input
low / open
PRIO audio mode is activated
PRIO-audio
high / closed
PRIO audio mode is activated
Please note:
•
at low/open the contact is always open
•
bei high/close ist der Kontakt immer geschlossen