Table 2) – DekTec DTM-3200 IP-ASI Converter User Manual

Page 43

background image

DTM-3200 – OEM Ethernet TSoIP Converter

User Manual

43

Figure 13 is the reply-sequence that may be executed after the read-command of Figure 12. After

addressing this device, the bytes from the command are repeated followed with the 4-byte

IP address.

Figure 13: Read subnet-mask reply

The reply consists of the following bytes:

Address and I

2

C write-bit (0x12 and ‘1’)

Category byte (0x03)

Setting byte (0x02)

Read byte (0x01)

Four IP-address bytes (decimal 192.168.100.13 or hexadecimal C0.A8.64.0D)

Checksum (0x0F, see Table 2)

Table 2: Checksum computation

Command

Reply

Address

0x12

0x12

Category

0x03

0x03

Setting

0x02

0x02

R/W

‘1’

‘1’

Data byte 3

-

0xC0

Data byte 2

-

0xA8

Data byte 1

-

0x64

Data byte 0

-

0x0D

Sum:

0x18

0x1F1

Checksum:

0xE8

0x0F