DTM-3200 – OEM Ethernet TSoIP Converter

User Manual

16

Please note that it is not required to select between I

2

C and RS-XXX: The DTM-3200 will

automatically use the interface on which it detects activity.

DIP switches for RS-232/485/422

For RS-232 or RS-485/422, the DIP switches have the following meaning:

Switch #

Description

1

Device address bit 0 – LSB (off = 0, on = 1)

2

Device address bit 1 – MSB (off = 0, on = 1)

3

RS-232 or RS-485/422 (off = RS-232; on = RS-485/422)

4

Baud-rate (off = 9600; on = 115200)

The device address bits are used for RS-485/422 only. The device address is 0x40 + two LSBs as

selected by the DIP switches. This means that the device address range is between 0x40 and 0x43.

DIP switches for I

2

C

For I

2

C communication, the DIP switches have the following meaning:

Switch #

Description

4, 3, 2, 1 Device address bit 3..0 (DIP switch off = 0, on = 1)

The I

2

C device address is 0x40 + four LSBs as selected by the DIP switches. This means that the I

2

C

device address range is between 0x40 and 0x4F.

3.4.5 Control connector

The pinning of the control connector is shown in the table below. It’s a single row pin header for

connecting the RS-232 (DCE), RS-485/422 or I

2

C control bus. The exact function of the signals

depends on whether RS-232 or RS-485/422 mode is selected by the DIP switches.

Pin

RS-232 mode (DCE) RS-485/422 mode

1

NC

NC

2

NC

NC

3

TX

TX/RX-

4

CTS

NC

5

RX

NC

6

RTS

TX/RX+

7

NC

NC

8

NC

NC

9

GND

GND

10

NC

NC

11

SDA

SDA

12

SCL

SCL

The pinning of this connector has been chosen in such a way that a 9-way flatcable with a press-fit

sub-D flatcable connector can be connected directly to pin 1 – 9, see the figure below.