beautypg.com

Dataman 48UXP User Manual

Page 70

background image

have selected an incorrect device as active device, or the device is

an older/newer version than the device supported by the

Dataman-48UXP.

Select the correct device as active device. If the error still occurs,

download the latest release of software from our web. If you are

sure that the device you are using uses the same programming

algorithm as a device that is supported, you can use device as active

device. You can then disable device code checking by setting the

Operating Options.

No device on socket!

The Dataman-48UXP does not detect a device in the socket.

The inserted device may be damaged. Replace it with a similar

device and try again.

No test version in the buffer!

The memory buffer does not contain any test vectors. When the

Dataman-48UXP tries to verify/function test a PLD, is displays this

message.

Download a file that contains test vectors before doing a function

test. Test vectors are usually included in JEDEC files.

Not enough memory available to complete operation!

There isn’t enough memory available to complete the requested

operation. Free some memory and retry the operation.

Over current detected!

A current higher than expected was found. This might indicate that

the device has been damaged or is short-circuit.

Check the socket or replace the device.