background image

menu and the contents is different from chip to chip), reference

to device configuration section. The last set up menu is statistic

configuration set up, detail of the statistic please reference to

statistic section of this manual.

Start the mass production mode

After fill and confirm all the above set up, the figure 4.2 screen

will display, inset the chip in the ZIF socket and the screen of

the ZIF socket will change color showing the chip insert into

the ZIF socket, green color indicate the pin has contact with the

ZIF socket properly.

No any error occur, the programmer will perform all the job

define by the operation option, after complete the programming

a beep will generated by PC and the good LED lamp will flash

indicate program chip successfully. Operator just remove the

chip and insert a new chip in the socket the programming

process will continuous till next error occur or the target

quantity / failure rate hit the statistic set up. No change in

color means no contact, red color shows program error when

attempt to program the chip, PC will generated two tone to

notice the operator.