get_timing_paths
Usage
get_timing_paths [-detail
[-fall_from_clock
[-from_clock
[-nworst
[-rise_to_clock
[-to_clock
Options
-detail
detail should be shown in the path report
-fall_from_clock
string matching)
-fall_to_clock
string matching)
-false_path: Report only paths that are cut by a false path assignment
-from
-from_clock
matching)
-hold: Option to report clock hold paths
-less_than_slack
less than the specified limit.
-npaths
as nworst, if nworst is specified)
-nworst
unspecified, there is no limit. If nworst is specified, but npaths is not, npaths
defaults to the same value as nworst
-pairs_only: When set, paths with the same start and end points are considered
equivalent. Only the worst case path for each unique combination is displayed.
-recovery: Option to report recovery paths
-removal: Option to report removal paths
-rise_from_clock
string matching)
-rise_to_clock
string matching)
-setup: Option to report clock setup paths
-show_routing: Option to display detailed routing in the path
-through
matching)
-to
-to_clock
string matching)
Description
Get a collection of path objects for the worst-case paths.