Status –19, Status – Altera Stratix IV GT 100G User Manual
Page 41

Chapter 6: Board Test System
6–19
Using the Board Test System
October 2010
Altera Corporation
Stratix IV GT 100G Development Kit User Guide
■
Detected errors
—Displays the number of data errors detected in the hardware.
■
Inserted errors
—Displays the number of errors inserted into the transaction
stream.
■
Insert Error
—Inserts a one-word error into the transaction stream each time you
click the button. Insert Error is only enabled during transaction performance
analysis.
■
Clear Errors
—Resets the Detected errors and Inserted errors counters to zeros.
Status
These controls display current transaction performance analysis information collected
since you last clicked Start:
■
PLL lock
—Shows the PLL locked or unlocked state.
■
Pattern sync
—Shows the pattern synced or not synced state. The pattern is
considered synced when the start of the data sequence is detected.
■
TX
and RX performance bars—Show the percentage of maximum theoretical data
rate that the requested transactions are able to achieve.
■
TX and RX performance
—Shows throughput in decimal form.
■
MBps
—Shows the number of megabytes of data analyzed per second for transmit
and receive.