Constant value loaded when aset is high. If omitted,
defaults to all 1s. The LPM_AVALUE parameter is
limited to a maximum of 32 bits. Altera recommends
that you specify this value as a decimal number for
AHDL designs.

No

Integer/
String

LPM_AVALUE

Constant value that is loaded on the rising edge of clock
when sset is high. If omitted, defaults to all 1s. Altera
recommends that you specify this value as a decimal
number for AHDL designs.

No

Integer/
String

LPM_SVALUE

Allows you to specify Altera-specific parameters in

VHDL Design Files (.vhd)

. The default is “UNUSED”.

No

String

LPM_HINT

Identifies library of parameterized modules (LPM)
entity name in VHDL Design Files.

No

String

LPM_TYPE