Technical details, 8technical details, 1 technical details – Pilz PSSu E S 2DO 2-T User Manual
Page 31

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
8-1
8.1
Technical details
8
Technical details
8
8000
Technical details
Technical details
8-
8.1
Technical details
8100
Technical details
8-
][Technische Daten PSSu Digitale E/A/K
Technical details
Application range
Standard
Module's device code
0400h
Number of ST output bits
2
Support in system environment A
from ST firmware version for other head modules
5
from ST firmware version PSSu H S PN
1
from ST firmware version PSSu WR S IDN
1
Support in system environment B
from head module ST firmware version
1.0.0
Electrical data
Internal supply voltage (module supply)
Supply voltage range of module supply
4.8 - 5.4 V
Module's current consumption
18 mA
Module's power consumption
0.09 W
Periphery's supply voltage (periphery supply)
Voltage range
16.8 - 30.0 V
Module's current consumption with no load
10 mA
Module's power consumption with no load
0.24 W
Max. power dissipation of the module
1.50 W
Outputs
Number of positive-switching single-pole semiconductor
outputs
2
Short circuit-proof
yes
Potential isolation between semiconductor output and
voltage for the internal module bus
yes
Typ. output current at “1” signal and rated voltage of sem-
iconductor output
2.00 A
Permitted current range
0.00 - 2.50 A
Max. pulsed current for t < 100 ms
12 A
Residual current at “0” signal
0.01 mA
Permitted loads
inductive, capacitive, resistive
Times
Max. processing time for semiconductor output when sig-
nal changes from “1” to “0”
0.600 ms
Max. processing time for semiconductor output when sig-
nal changes from “0” to “1”
0.010 ms
Environmental data
Climatic suitability
EN 60068-2-14, EN 60068-2-1, EN 60068-2-2,
EN 60068-2-30, EN 60068-2-78
Ambient temperature in accordance with EN 60068-2-14
0 - 60 °C
-40 - 70 °C coated version (-T)
Storage temperature in accordance with EN 60068-2-1/-2 -25 - 70 °C
-40 - 70 °C coated version (-T)
Climatic suitability in accordance with EN 60068-2-30,
EN 60068-2-78
93 % r. h. at 40 °C
Condensation
no
yes coated version (-T)
Max. operating height above sea level
5000 m coated version (-T)
EMC
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-6-2,
EN 61000-6-4